Counterflow closed cooling tower
Counterflow closed cooling tower
Counterflow closed cooling tower
Counterflow closed cooling tower
Counterflow closed cooling tower
Counterflow closed cooling tower
Counterflow Closed Circuit Cooling Tower

The counterflow closed circuit cooling tower is designed for indirect industrial process cooling. The process fluid circulates inside an enclosed heat exchange coil, while spray water and airflow remove heat from the coil surface without direct contact with the process fluid.

 

Key Specifications

Cooling Medium: Water, oil and other compatible liquids

Cooling Method: Closed-loop indirect cooling

Airflow: Counterflow

Heat Exchange Coil: Copper tube or stainless steel tube

Casing Material: 304 stainless steel, galvanized steel or magnesium-aluminum-zinc coated steel

Application: Industrial process cooling

 

Customization

Cooling capacity, coil material, casing material and configuration can be selected according to process fluid, flow rate, temperature requirements, ambient conditions and installation requirements.


Inquire now
add to the cart

Share:

Product Details

Counterflow Closed Circuit Cooling Tower

A counterflow closed circuit cooling tower is an indirect evaporative cooling system designed to remove heat from industrial process fluids while keeping the process fluid inside a closed heat exchange coil.

Unlike an open cooling tower, the process fluid does not directly contact the cooling air or spray water. Heat is transferred through the coil wall to the spray water and airflow, helping maintain the cleanliness and stability of the circulating process fluid.

The counterflow design directs cooling air and spray water in opposite directions to promote heat transfer. The system can be configured for water, oil and other compatible liquids according to the required cooling capacity and operating conditions.

 

How Does a Counterflow Closed Circuit Cooling Tower Work?

The cooling process is based on indirect heat exchange between the process fluid, heat exchange coil, spray water and cooling air.

The hot process fluid enters the enclosed heat exchange coil and flows through the coil. Heat from the process fluid is transferred through the coil wall to the water film on the outside of the coil.

At the same time, the spray system distributes water over the external surface of the heat exchange coil. The cooling fan draws air through the tower in the opposite direction to the falling spray water.

As the air and water move through the heat exchange section, part of the spray water evaporates and carries heat away with the exhaust air. The remaining water is collected and recirculated through the spray system.

The cooled process fluid then leaves the coil and returns to the industrial process.

Cooling Process

Hot Process Fluid → Heat Exchange Coil → Heat Transfer → Spray Water and Airflow → Heat Removal → Cooled Process Fluid

This indirect cooling method keeps the process fluid separated from the external cooling environment during normal operation.

 

Counterflow Cooling Principle

The counterflow configuration is characterized by opposite flow directions between the cooling air and spray water.

  • Process fluid: Circulates inside the closed heat exchange coil

  • Spray water: Flows downward across the external coil surface

  • Cooling air: Flows upward through the heat exchange section

  • Heat transfer: Takes place through the coil wall

  • Evaporative cooling: Removes additional heat from the spray water

The counterflow arrangement provides an effective heat transfer environment and allows the cooling tower to be designed around specific process temperatures, fluid flow rates and local ambient conditions.

 

Main Components of the Cooling Tower

The main components may vary according to the selected model and configuration, but a typical counterflow closed circuit cooling tower includes the following:

Heat Exchange Coil

The heat exchange coil carries the process fluid and transfers heat to the external cooling system. Copper or stainless steel tubing can be selected according to fluid characteristics and corrosion requirements.

Spray Water System

The spray system distributes cooling water across the external surface of the heat exchange coil to form an even water film and support evaporative heat transfer.

Spray Water Pump

The pump circulates water from the collection basin to the spray distribution system.

Cooling Fan

The fan moves air through the heat exchange section and removes sensible heat and evaporated moisture from the tower.

Water Collection Basin

Non-evaporated spray water returns to the collection basin and is recirculated through the system.

Drift Eliminator

The drift eliminator helps reduce the amount of water droplets carried out of the cooling tower with the exhaust airflow.

Casing and Support Structure

The casing protects the internal components and can be manufactured from different materials according to environmental and corrosion requirements.

 

Key Features and Benefits

Closed-Loop Process Fluid Protection

The process fluid remains inside the heat exchange coil rather than being directly exposed to the atmosphere or spray water. This helps reduce the risk of external contaminants entering the process loop.

Efficient Counterflow Heat Transfer

The cooling air moves upward while spray water moves downward, creating an opposite-flow arrangement that supports efficient heat transfer.

Flexible Cooling Medium

The system can be designed to cool water, oil and other compatible liquids. Final material selection should consider fluid temperature, viscosity, chemical characteristics and operating pressure.

Multiple Heat Exchange Materials

Copper and stainless steel tubes are available for different applications. Stainless steel can be considered where higher corrosion resistance is required.

Flexible Casing Materials

Available casing options include 304 stainless steel, galvanized steel and magnesium-aluminum-zinc coated steel. The appropriate material depends on ambient conditions and project requirements.

Reduced Exposure to External Contaminants

Because the process fluid is contained within a closed coil, the cooling system can help maintain a more controlled process-fluid environment compared with direct-contact open cooling systems.

Suitable for Industrial Process Cooling

The equipment can be integrated into industrial cooling loops where process heat needs to be continuously removed while maintaining separation between the process fluid and the cooling water.

 

Closed Circuit Cooling Tower vs Open Cooling Tower

Choosing between a closed circuit and open cooling tower depends on the process requirements, fluid characteristics and desired level of process-fluid isolation.

Feature

Closed Circuit Cooling Tower

Open Cooling Tower

Process fluid

Flows inside enclosed coil

Cooling water is directly exposed to air

Process fluid contact with air

No direct contact

Direct contact for cooling water

Process fluid contamination risk

Lower

More dependent on system configuration

Heat transfer

Indirect through coil wall

Direct water-air heat exchange

Fluid cleanliness

Easier to control

Requires closer water treatment management

Suitable applications

Industrial process fluids and sensitive systems

General circulating water cooling

Cooling configuration

Coil + spray water + airflow

Water + airflow

 

Industrial Applications

Counterflow closed circuit cooling towers can be used for industrial processes where indirect heat removal and process-fluid isolation are important.

Typical applications include:

  • Industrial process cooling

  • Chemical processing equipment

  • Hydraulic and lubrication systems

  • Air compressor cooling

  • Furnace and induction heating equipment

  • Manufacturing machinery

  • Power and energy equipment

  • Industrial refrigeration systems

  • Heat exchanger cooling

  • Process equipment cooling

For projects in Southeast Asia, South America and the Middle East, cooling tower selection should take local ambient conditions, wet-bulb temperature, water quality, dust exposure, corrosion conditions and available installation space into consideration.

 

Cooling Tower Selection Guide

Selecting a suitable closed circuit cooling tower requires more than simply matching the equipment by nominal cooling capacity.

Before selecting a model, provide the following operating information.

1. Process Fluid

Specify the fluid that needs to be cooled, such as:

  • Water

  • Oil

  • Glycol solution

  • Other compatible liquids

2. Flow Rate

Provide the required process-fluid flow rate, normally expressed in m³/h.

3. Fluid Inlet Temperature

Provide the temperature of the process fluid entering the cooling tower.

4. Required Outlet Temperature

Specify the target temperature after cooling.

5. Local Ambient Conditions

Provide the design:

  • Wet-bulb temperature

  • Dry-bulb temperature

  • Elevation

  • Seasonal operating conditions

6. Installation Conditions

Provide information about:

  • Available installation space

  • Indoor or outdoor installation

  • Local water quality

  • Ambient dust

  • Corrosion exposure

  • Electrical power supply

  • Noise requirements

7. Material Requirements

The coil and casing material should be selected according to the process fluid and operating environment.

 

Technical Parameters

Design conditions: wet bulb temperature: 28 °C, dry bulb temperature: 31.5 °C, atmospheric pressure: 9.94X 10⁴ PA.

Parameter Model

Standard Cooling Capacity (kcal/h)

Circulation flow(m³/h)

Dimensions (mm)

Fan Power (kw)

Fan Diameter (mm)

Spray pump power(kw)

Inlet and outlet DN

Overflow Sewage DN

Hydration DN

Running weight (kg)

37℃-32℃

42℃-37℃

50℃-42℃

l

w

h

BCNL-10T

50000

10

16

16

1350

750

2390

0.37

600

0.75

65

25

25

860

BCNL-15T

75000

15

24

24

1950

700

2390

0.37

600

0.75

65

25

25

1020

BCNL-30T

150000

30

48

48

2350

970

2390

0.37*2

600

1.1

65

25

25

1600

BCNL-40T

200000

40

64

64

2850

9700

2390

0.75*2

800

1.5

65

25

25

2200

BCNL-50T

250000

50

80

80

2850

1500

2390

1.5*2

900

2.2

80

25

25

2800

BCNL-65T

325000

65

104

104

2850

1630

2390

1.5*2

900

2.2

100

25

25

321 J

BCNL-80T

400000

80

128

128

2850

2160

2390

1.5*2

900

2.2

100

50

25

4100

BCNL-125T

625000

125

200

200

4250

2500

2390

1.5*3

900

4

100

50

25

6630

BCNL-150T

750000

150

240

240

4750

2400

3200

3*3

1000

4

125*2

50

25

7500

BCNL-200T

100000

200

320

320

5250

2700

3200

3*3

1000

5.5

125*2

50

25

10500

BCNL-240T

1200000

240

384

384

6350

2700

3200

4*3

1200

5.5

150*2

50*2

25

12000

BCNL-360T

1800000

360

576

576

9600

3000

4800

7.5*4

2000

5.5*2

125*4

50*2

40*2

22200

BCNL-450T

2250000

450

720

720

10600

3000

5200

7.5*5

1800

7.5*2

150*4

50*2

40*2

25000

BCNL-500T

2500000

500

800

800

11500

3000

5200

7.5*5

2000

7.5*2

150*4

50*2

40*2

27500

 

Customization Options

The counterflow closed circuit cooling tower can be configured according to the requirements of different industrial processes.

Customization may include:

  • Cooling capacity

  • Heat exchange coil material

  • Casing material

  • Process fluid type

  • Process-fluid flow rate

  • Inlet and outlet temperature

  • Fan configuration

  • Pump configuration

  • Control system

  • Installation requirements

The final configuration should be determined according to actual process conditions and required cooling performance.

 

Why Choose a Closed Circuit Cooling System?

A closed circuit cooling system can be considered when the process requires:

  • Isolation of the process fluid from cooling water

  • Stable process-fluid circulation

  • Reduced exposure to external contaminants

  • Indirect heat transfer

  • Flexible material selection

  • Continuous industrial cooling

  • Adaptation to demanding site conditions

For industrial projects, selecting the cooling system according to actual operating conditions is essential for achieving the required cooling performance and long-term operating stability.

 

Frequently Asked Questions

What is a counterflow closed circuit cooling tower?

A counterflow closed circuit cooling tower is an indirect cooling system in which the process fluid flows inside a closed heat exchange coil while spray water and cooling air remove heat from the coil.

 

What fluids can a closed circuit cooling tower cool?

The system can be configured to cool water, oil and other compatible liquids. The appropriate coil material and configuration depend on the fluid properties and operating conditions.

 

Does the process fluid contact the spray water?

No. The process fluid remains inside the heat exchange coil, while spray water flows over the outside of the coil. Heat is transferred through the coil wall.

 

What is the advantage of a counterflow design?

The cooling air and spray water move in opposite directions through the heat exchange section. This arrangement supports effective heat transfer and can be adapted to different process cooling conditions.

 

Can the coil material be customized?

Yes. Copper and stainless steel tubes can be selected according to the process fluid, temperature, corrosion requirements and operating conditions.

 

Can the cooling tower be used in hot climates?

Yes, but the equipment should be selected according to the actual local design wet-bulb temperature, dry-bulb temperature and required process-fluid outlet temperature. This is particularly important for projects in hot regions.

 

How do I select the right cooling tower model?

Provide the process fluid, flow rate, inlet temperature, required outlet temperature, local wet-bulb temperature and installation conditions. These parameters can be used to evaluate the required cooling capacity and equipment configuration.

 

Request a Counterflow Closed Circuit Cooling Tower Solution

Looking for a suitable counterflow closed circuit cooling tower for your industrial process?

Send us your operating conditions, including:

  • Process fluid

  • Flow rate

  • Inlet temperature

  • Required outlet temperature

  • Design wet-bulb temperature

  • Installation location

  • Available space

  • Material requirements

Our technical team can evaluate the cooling requirements and recommend a suitable configuration for your application.