Equipment Principle
1、Boiling point of water as a function of vacuum level
Under negative pressure, the boiling point of water is below 100 degrees, correspondingly
2.Heat pump (air conditioner) dehumidification.
Heat pump operation is the process of cooling and heating at the same time.
Under vacuum, the wastewater is heated up in the boiling chamber using a heating system and boils to form water vapor at about 35°C. The water vapor enters the condensation chamber to form condensate under the action of the refrigeration system and is then discharged. The water vapor enters the condensation chamber and forms condensate under the action of the refrigeration system, which is then discharged.
Temp (℃) | Vac(kpa) | Temp (℃) | Vac (kpa) | Temp (℃) | Vac (kpa) | Temp(℃) | Vac(kpa) |
20 | -98.7 | 40 | -93.7 | 60 | -81.2 | 80 | -53.9 |
21 | -98.6 | 41 | -93.3 | 61 | -80.3 | 81 | -51.9 |
22 | -98.4 | 42 | -92.9 | 62 | -79.3 | 82 | -49.9 |
23 | -98.3 | 43 | -92.5 | 63 | -78.3 | 83 | -47.8 |
24 | -98.1 | 44 | -92.0 | 64 | -77.2 | 84 | -45.6 |
25 | -97.9 | 45 | -91.5 | 65 | -76.1 | 85 | -43.4 |
26 | -97.7 | 46 | -91.0 | 66 | -75.0 | 86 | -41.1 |
27 | -97.5 | 47 | -90.5 | 67 | -73.8 | 87 | -38.7 |
28 | -97.3 | 48 | -89.9 | 68 | -72.6 | 88 | -36.3 |
29 | -97.1 | 49 | -89.4 | 69 | -71.3 | 89 | -33.8 |
30 | -96.8 | 50 | -88.8 | 70 | -70.0 | 90 | -31.2 |
31 | -96.6 | 51 | -88.2 | 71 | -68.0 | 91 | -28.5 |
32 | -96.3 | 52 | -87.5 | 72 | -67.0 | 92 | -25.7 |
33 | -96.1 | 53 | -86.8 | 73 | -65.7 | 93 | -22.8 |
34 | -95.8 | 54 | -86.1 | 74 | -64.2 | 94 | -19.8 |
35 | -95.5 | 55 | -85.4 | 75 | -62.6 | 95 | -16.8 |
36 | -95.2 | 56 | -84.6 | 76 | -61.0 | 96 | -13.6 |
37 | -94.8 | 57 | -83.8 | 77 | -59.3 | 97 | -10.4 |
38 | -94.5 | 58 | -83.0 | 78 | -57.5 | 98 | -7.0 |
39 | -94.1 | 59 | -82.1 | 79 | -55.7 | 99 | -3.6 |
Equipment Operating Steps
Equipment advantages
Energy saving and high efficiency:Adopting heat recovery technology, fully enclosed design, no waste heat emission, 1 kWh of electricity evaporates
Safety and environmental protection: The evaporation process is carried out below 40 degrees, and the system operates safely. The equipment is fully enclosed and there is no exhaust gas emission. The condensed water produced by evaporation can be directly reused or discharged.
Maintenance-free system:Except for daily inspections, the entire equipment is maintenance-free.
Intelligence: All operations can be controlled remotely, and the equipment operation status can be monitored in real time. If there is any abnormality, the parameters can be adjusted remotely.
Strong adaptability: The only heat source is electricity, no heat, steam or auxiliary heat source is required.
Equipment model and configuration